What This Actually Covers
-
FAQ
-
1. What's the real difference between a Danfoss differential pressure switch and a standard high/low pressure switch?
-
2. My Danfoss RT pressure switch keeps failing on an industrial refrigeration system — what's actually going wrong?
-
3. How do I wire a Danfoss KP or RT switch when the wiring diagram is missing?
-
4. I'm also replacing a 200 amp single phase manual transfer switch at the same site — does that interact with the pressure controls?
-
5. How do I clean an air filter that's throwing off pressure switch readings?
-
6. Why does Motorcraft FA-1611 air filter keep showing up in my searches for pressure switch parts?
-
7. What's the real lead time on a Danfoss pressure switch when I need it today?
-
8. Is the "set it and forget it" era of pressure switches over?
-
1. What's the real difference between a Danfoss differential pressure switch and a standard high/low pressure switch?
-
One Last Thing
What This Actually Covers
I run emergency parts coordination for industrial clients — mostly HVAC, refrigeration, and plant maintenance teams that discover a failed control on a Friday afternoon. In the last 18 months I've coordinated 340+ rush orders, and pressure switches (specifically the Danfoss KP and RT series) are consistently in the top three line items.
These are the questions I get asked most. Not the marketing version — the ones that come up when someone's standing in a mechanical room with a multimeter and a deadline.
FAQ
1. What's the real difference between a Danfoss differential pressure switch and a standard high/low pressure switch?
A standard high or low pressure switch trips on a single pressure threshold. A differential pressure switch measures the difference between two points — which is why you see differential pressure switch Danfoss models (KP 35, KP 36, KP 38) monitoring filter pressure drop, pump flow, and refrigerant oil pressure.
Here's the thing most people don't realize: on the KP series, the differential range is not simply the factory setpoint minus a fixed offset. It's mechanically tuned through the range screw, and a lot of field replacements go wrong because someone assumed the new switch was pre-calibrated to the old one's readings. It wasn't. Verify with a gauge before you trust the dial.
For industrial refrigeration, the RT series is the traditional reference point. RT 116, RT 117, RT 5 — these show up in ammonia and large commercial systems and are built to a different durability spec than the KP line. They're not interchangeable, even when the pressure ranges overlap.
2. My Danfoss RT pressure switch keeps failing on an industrial refrigeration system — what's actually going wrong?
In my experience, roughly 7 out of 10 "failed" Danfoss RT pressure switch industrial units that get returned test fine on the bench. The problem is upstream.
Three things I check first, in this order:
- Contamination in the sensing line. Oil, moisture, or debris blocking the capillary tube will mimic a failed switch every time.
- Setpoint drift from vibration. Packaged refrigeration skids shake. Range screws walk. This is why the RT series has a locking plate — and why half the units I see in the field have it backed off.
- Actual contact wear. This is the one real failure mode. If the switch has cycled through 500k+ operations, the microswitch contacts can pit. No amount of adjustment fixes that.
Diagnostic you can run in under 10 minutes: disconnect, apply a known pressure with a hand pump, and listen for the click while watching continuity. If it clicks but the contacts don't change state, it's the switch. If it doesn't click at all, the bellows is stuck — usually contamination.
3. How do I wire a Danfoss KP or RT switch when the wiring diagram is missing?
This comes up constantly — someone's replacing a legacy unit and the panel drawing disappeared three plant managers ago. I should add that you should never rely on wire colors alone; Danfoss has used different color conventions across production years.
Practical approach:
- KP series: three terminals, SPDT. The common is typically marked, and the other two are NO and NC. Verify with a continuity tester — don't guess.
- RT series: some models are SPDT, some are DPDT. Count the terminals first. Four terminals means dual-pole and you have a choice of contact configuration.
One habit that's saved me from a $12,000 mistake: photograph the old switch's wiring before you disconnect it, then label the wire ends with tape. The 30 seconds it takes is worth it every time.
4. I'm also replacing a 200 amp single phase manual transfer switch at the same site — does that interact with the pressure controls?
Yes, and this is where people get surprised. A 200 amp single phase manual transfer switch in an HVAC or refrigeration plant doesn't just move power — it changes which circuits are live during a generator run. If your pressure controls are wired to a circuit that gets dropped during transfer, your compressors are running unprotected.
What to check before you swap the transfer switch:
- Are the pressure switch control circuits on the standby side or the normal side?
- Do the pressure switches need to stay energized during transfer to prevent a locked-rotor condition on restart?
- Is the transfer switch rated for the inductive load of compressor contactors, or just the resistive load on the nameplate?
I've seen a plant lose two compressors because the transfer switch dropped control power for 90 seconds during a utility outage. The pressure switches did their job — tripped on low oil pressure — but nobody had wired the restart sequence correctly.
5. How do I clean an air filter that's throwing off pressure switch readings?
Depends entirely on the filter type. And this is a place where I've watched people do real damage.
If it's a washable metal mesh or synthetic media filter (common in industrial HVAC intake plenums), back-flush with low-pressure water, dry completely, and inspect for media separation. If it's a pleated paper filter — don't wash it. I know the internet says you can, but the media fibers swell and you lose the porosity that made the filter work in the first place. Replace it.
Why this matters for pressure switches: a clogged intake filter raises the pressure differential across the fan or blower, and your differential pressure switch will trip — sometimes repeatedly — because the system genuinely is over-pressure. Cleaning or replacing the filter is the fix; adjusting the switch setpoint is not.
6. Why does Motorcraft FA-1611 air filter keep showing up in my searches for pressure switch parts?
Because search engines are bad at separating automotive cabin/engine filters from industrial process filters. They shouldn't be in the same shopping list.
The Motorcraft FA-1611 air filter is an automotive engine air filter. It has nothing to do with Danfoss pressure switches, industrial refrigeration, or plant HVAC. If you landed here looking for one, you probably want an auto parts supplier, not an industrial controls distributor.
That said — it's worth mentioning that in a plant maintenance context, air filters for compressed air systems (coalescing filters, particulate filters) absolutely do interact with pressure switch performance. Different product, same word. If your compressor's air filter is clogged, you'll see pressure switches tripping on high discharge temps that look like switch failures but aren't.
7. What's the real lead time on a Danfoss pressure switch when I need it today?
Depends on series and whether you're flexible on the setpoint.
KP series models (KP 1, KP 15, KP 35) are commonly stocked by industrial distributors — same-day or next-day is realistic if you can confirm physical inventory. RT series industrial switches are a different story. As of January 2025, my working assumption for RT 116 and RT 117 is 2–4 weeks from factory, with expedite possible at additional cost.
Here's something vendors won't tell you: "in stock" on a distributor's web portal frequently means "in stock at our regional warehouse" — not at the branch you're driving to. Call the branch. Ask them to physically count the units and read you the label. I've saved myself three unnecessary 4-hour drives this way.
8. Is the "set it and forget it" era of pressure switches over?
What was best practice in 2018 may not apply in 2025 — and this is a place where the industry has genuinely moved. Five years ago you could install a mechanical pressure switch, set the range screw, and trust that it would hold within ±5% for a decade in a clean environment. In dirty environments or high-vibration installations, that assumption was always optimistic.
The fundamentals haven't changed — a pressure switch is still a mechanical device that senses pressure and opens or closes contacts. But the execution has transformed. Modern Danfoss units have better sealing, tighter manufacturing tolerances, and more reliable contact materials. What that means in practice: fewer catastrophic failures, more gradual setpoint drift. The switch doesn't die — it slowly lies to you.
My recommendation: pull and verify setpoints every 18 months on critical refrigeration controls. Not because the switch is bad, but because drift is real and the failure mode is silent. That's the trade-off most people miss when they assume "set and forget" still applies.
One Last Thing
If you're in an emergency and can't find an exact Danfoss replacement, the wrong move is to substitute a different series because the port thread matches. Match the function (differential vs. single-point, SPDT vs. DPDT, pressure range, and — critically — the electrical rating against your compressor contactor), then size the replacement. The 30 minutes you spend checking the spec sheet will save the two days you'd spend explaining a compressor failure to your plant manager.